EXTECH INSTRUMENTS MN26T CALIBRATION and EXTECH INSTRUMENTS MN26T REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS MN26T Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS MN26T   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS MN26T Auto Ranging MiniTec Digital MultiMeter with Temp

The Extech MN26T Auto Ranging MiniTec Digital MultiMeter features 4000 counts on large LCD with full function indication. Specifications. DC Voltage Ranges: 200mV, 2V, 20V, 200V, 600V. DC Voltage Maximum Resolution: 0.1 mV. DC Voltage Accuracy: ± (0.5% reading + 2 digits). AC Voltage Ranges: 200V, 600V. AC Voltage Maximum Resolution: 0.1 V. AC Voltage Accuracy (Frequency 50/60Hz): ± (1.5% reading + 5 digits). DC Current Ranges: 200mA, 10A. DC Current Maximum Resolution: 100 µA. DC Current Accuracy: 200mA ± (1.2% reading + 2 digits), 10A ± (2.0% reading + 2 digits). AC Current Ranges: 200mA, 10A. AC Current Maximum Resolution: 100 µA. AC Current Accuracy: 200mA ± (1.8% reading + 5 digits), 10A ± (3.0% reading + 5 digits). Resistance Ranges: 200, 2k, 20k, 200k, 2Mohm. Resistance Maximum Resolution: 0.1 ohm. Resistance Accuracy: 200, 2k, 20k, 200kohm ± (0.8% reading + 2 digits), 2Mohm ± (1.0% reading + 2 digits). Capacitance Ranges: 4 nF, 40 nF, 400 nF, 4 µF, 40 µF, 200 µF. Capacitance Maximum Resolution: 0.001 nF. Capacitance Basic Accuracy: ±3.5%. Frequency Ranges: 0.001 Hz to 10 MHz. Frequency Maximum Resolution: 0.001 Hz. Frequency Basic Accuracy: ±1.5%. Temperature Ranges: 0 to 1400°F (0 to 760°C ). Temperature Maximum Resolution: 1°F/°C. Temperature Basic Accuracy: ±3.0%. Duty Cycle: 0.1% to 99.9%. Duty Cycle Maximum Resolution: 0.1%. Duty Cycle Basic Accuracy: ±1.2%. Display: 3 1/2 digit, 2000 count LCD, 0.5” digits. Diode Test: Test current of 0.3mA maximum, open circuit voltage 1.5V DC typical.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS MN26T. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your EXTECH INSTRUMENTS MN26T CALIBRATION and/or EXTECH INSTRUMENTS MN26T Auto Ranging MiniTec Digital MultiMeter with Temp REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: